Independent study platform. Not affiliated with the Red Seal Program or the Government of Canada. Read the full notice

Refrigeration & AC Systems Mechanic · Red Seal 313A

313A Practice Exam — know your real Refrigeration & AC score before exam day.

Free, Red Seal–style practice for the 313A Refrigeration and Air Conditioning Mechanic certification. Every test is weighted to the official exam blueprint — more than half procedure, the rest recall and critical thinking, the way the real exam is built — so the score you get here reflects the score you'd get there.

No account to try · 5 free questions · 550 in the bank

A refrigeration mechanic studying for the Red Seal 313A exam on a tablet beside a rooftop unit
Field study313A Refrigeration & AC

The 313A exam at a glance

What you're walking into.

Questions
125
Time limit
4 hrs
Work activities
6
Our bank
550

Question mix — weighted to the blueprint

Recall 20–30%Procedural 50–60%Critical 10–20%

More than half the paper asks you to carry out a procedure — the largest procedural share of any mechanical trade on this site. Only one question in four asks you to state a fact. The rest asks you to take superheat and subcooling from a gauge set, complete a charge, set a control, work a load from the formula sheet, or reason from a full set of readings to the one cause that fits — which is exactly where recall-only question banks leave you exposed.

What the 313A covers

Six major work activities.

The occupational standard groups the trade into six major work activities, 15 tasks and 57 sub-tasks. The question counts below are the official blueprint weightings — our 550-question bank is built to that same map, with every sub-task covered.

  1. A

    Performs common occupational skills · 13 questions

    Safety-related functions and lock-out, tools and equipment (brazing, recovery, evacuation, charging, diagnostic and rigging gear), organizing work from drawings and documentation, and communication and mentoring.

  2. B

    Performs routine trade activities · 19 questions

    Work site preparation and materials handling, then the core trade activities: brazing and soldering, leak and pressure tests, evacuation, refrigerants, gases and oils, field wiring, and sealants and adhesives.

  3. C

    Plans installation · 18 questions

    Planning HVAC/R systems (11 questions) and control systems (7): verifying parameters and requirements, selecting equipment and components, determining placement, and material take-off.

  4. D

    Performs installation · 26 questions

    Installing HVAC/R systems (16 questions): confirming layout, assembling and placing equipment, fasteners and hangers, piping and tubing, and the holding charge. Installing control systems (10): placing and connecting components.

  5. E

    Performs commissioning · 21 questions

    HVAC/R systems (13 questions): pre-start-up checks, start-up, completing the charge, and setting up primary and secondary components. Control systems (8): start-up checks and verifying or setting operating parameters.

  6. F

    Performs maintenance and service · 28 questions

    Maintaining HVAC/R systems (8 questions), servicing them — troubleshooting and repair (11) — and maintaining and servicing control systems (9): inspection, troubleshooting, calibrating operating and safety controls, and repair.

Where our numbers come from

Every question, anchored to the standard.

HVAC/R practice banks quietly go wrong in two ways: a superheat, subcooling or charge figure that belongs to one manufacturer presented as a universal number, and formulas tested as memory when the exam hands you a formula sheet. Every question in our 313A bank is anchored to a sub-task of the occupational standard and verified against it, with all four options explained. The formula sheet and acronym list are provided at the exam sitting — Btuh = 4.5 × CFM × ΔH, 1.08 × CFM × ΔT, 500 × USGPM × ΔT, psia = psig + 14.7, 12 000 Btuh per ton — so our airflow, water-flow and load questions are written to be worked from that sheet, and we never test recall of the formulas themselves. Where a value is genuinely set by the manufacturer, such as a subcooling target or a nameplate charge, the question gives it in the stem or tests the method and the relationship instead of inventing a figure. The question counts above are the Red Seal Program's own exam breakdown for Refrigeration and Air Conditioning Mechanic, and every question is mapped to a sub-task of the Red Seal Occupational Standard. The Red Seal Program has published a 2024 standard and says new exams based on it are under development; until then the current exam and this bank follow the 2019 standard. For what each block covers and where to spend your study time, read the 313A exam guide. Read how our questions are made.

Last reviewed against the Red Seal Program's published exam information.

Try three from the bank

Three 313A practice questions, answers included.

Three questions from three different work activities — one recall, one procedural, one critical-thinking, the way the exam is built. Pick an answer, then open the explanation. Every question in the bank explains all four options, not just the right one.

  1. Critical thinking · Performs maintenance and service

    An R-134a medium-temperature walk-in cooler with a TXV runs continuously. Readings: suction 35 kPa (5 psig, saturated −3 °F); suction line 40 °F; discharge 915 kPa (133 psig, saturated 104 °F) at 29 °C (85 °F) ambient; liquid line 92 °F; sight glass clear; no temperature drop across the drier or LLSV; opening the TXV adjustment fully makes no change. Which cause fits?

    1. A plugged liquid-line filter-drier
    2. Low refrigerant charge
    3. The TXV power element (bulb) has lost its charge
    4. The TXV bulb is loose and sensing warm air
    Show the answer

    C. Correct. Superheat is 40 − (−3) = 43 °F with normal 12 °F subcooling, a clear sight glass and no restriction upstream: liquid reaches the valve but the valve will not open, and adjustment has no effect. A bulb that has lost its charge closes the valve. Replace the power element or valve.

  2. Procedural · Performs commissioning

    On an R-134a reach-in cooler the suction pressure at the evaporator outlet is 22 psig (152 kPa), which the P/T chart shows as 24 °F saturated. The suction line at the same point measures 36 °F. What is the evaporator superheat?

    1. 2 °F (1.1 K)
    2. 12 °F (6.7 K)
    3. 14 °F (7.8 K)
    4. 24 °F (13.3 K)
    Show the answer

    B. Correct. Superheat = suction-line temperature − saturated suction temperature from the P/T chart = 36 − 24 = 12 °F, a 6.7 K difference. The pressure is only the way into the chart. For a zeotropic blend (an R-4xx refrigerant) the chart's dew-point column would be used; R-134a is a pure fluid with a single saturation column.

  3. Recall · Performs routine trade activities

    You are brazing a copper suction line to the steel stub on a semi-hermetic compressor. Which filler and flux selection is correct?

    1. A BAg silver-bearing alloy with a suitable brazing flux
    2. A BCuP copper-phosphorus alloy without flux, as on copper-to-copper joints
    3. A BCuP copper-phosphorus alloy with flux to compensate for the steel
    4. A 95/5 tin-antimony solder with paste flux, since the joint is on the low side
    Show the answer

    A. Correct. Copper to steel (or to brass) is joined with a BAg silver alloy and flux. The flux removes oxides from the steel and lets the alloy wet it. The same rule applies to copper-to-brass valves. BCuP alloys are for copper to copper only.

Start free 313A practice

Want ten more with every option explained? Free 313A practice questions — no account, no email, printable.

Why practice scores mislead

You can ace recall and still fail the 313A.

Most question banks drill what you can recall, because recall questions are cheap to write. On the 313A that covers 20 to 30 percent of the paper at best. The other 70 to 80 percent asks you to do the job: procedural questions that ask you to take superheat and subcooling from a gauge set and a P/T chart, charge a blend as liquid, set a low-pressure control for pump-down or braze under a nitrogen purge, and critical-thinking questions that hand you a full set of readings and ask which one cause fits. That gap is why people walk in confident and walk out surprised. TicketPrep weights every test to the published blueprint, so a 78 here means 78 there — and a weak block here is a weak block there.

How TicketPrep prepares you

Built like a study tool, not a quiz app.

01

Weighted to the blueprint

Every test matches the published 313A weightings — recall, procedure and critical thinking in the same proportions the real exam is built from.

02

Every answer explained

Learn why the right answer is right — and why each of the other three is wrong. That's where the learning happens.

03

Timed mock exams

Full-length tests that match the real 125-question count and 4-hour limit, so exam day feels familiar.

04

Know your weak areas

Your score broken out by work activity, so you always know which block to drill next.

313A questions

Before you start.

How many questions are on the 313A Red Seal exam?
125 multiple-choice questions with a 4-hour writing time and a 70% pass mark — 88 correct answers — distributed across six major work activities. Between 50 and 60 percent are procedural and application questions; 20 to 30 percent are knowledge and recall, and 10 to 20 percent are critical thinking. Nationally the trade is called Refrigeration and Air Conditioning Mechanic; Ontario certifies it as Refrigeration and Air Conditioning Systems Mechanic, a compulsory trade with code 313A, and writes the same interprovincial exam. It is not the same trade as Ontario's 313D Residential Air Conditioning Systems Mechanic, which has no Red Seal.
Is the 313A practice exam free?
Yes. You can try five free sample questions with no account. You see right or wrong as you go, and your email unlocks the written explanation for every option plus a one-page study guide. The full 550-question bank — 400 Standard plus 150 Advanced — and mock exams come with Exam Pass — a one-time $69 purchase for 120 days of access, not a subscription.
What does the 313A exam cover?
Common occupational skills; routine trade activities (brazing and soldering, leak and pressure tests, evacuation, refrigerants, gases and oils, field wiring, sealants and adhesives); planning the installation of HVAC/R and control systems; performing the installation (layout, assembly, placement, hangers, piping, holding charge, control wiring); commissioning (pre-start checks, start-up, completing the charge, setting up components and controls); and maintenance and service, including troubleshooting and calibrating operating and safety controls — six major work activities in all.
Do I have to memorize the formulas?
No. The Red Seal Program provides a formula sheet and an acronym list at the exam sitting. The sheet is imperial — Btuh = 4.5 × CFM × ΔH, 1.08 × CFM × ΔT, 500 × USGPM × ΔT, psia = psig + 14.7, 12 000 Btuh per ton and the rest, with a conversion table — and our calculation questions are written to be worked from it, so you practise choosing and applying the right formula the way the exam presents it rather than recalling it from memory.
Are these real 313A exam questions?
No. These are independent, Red Seal–style practice questions written for study, each mapped to the public occupational standard for the trade. Anyone selling "real exam questions" is breaking the Red Seal Program's terms — we don't do that.

Find out where you actually stand.

Five free questions, no account needed. See how you did as you go, then enter your email to unlock every explanation. About five minutes.

Then Exam Pass is $69 one-time for 120 days of access — not a subscription — with a 7-day money-back guarantee.