Field Safety Representative · Electrical · British Columbia
BC FSR Exam Practice: Field Safety Representative Class A, B and C
Five original BC FSR exam questions to start, from all four units: a journeyperson taking his own client, an empty underground raceway, an outdoor service disconnect on a new house, and two load calculations, a house under Rule 8-200 and a strata unit under Rule 8-202. Most candidates write Class B, so treat this as your FSR Class B practice exam first: Classes B and C share one code scope, the whole Canadian Electrical Code except Section 36, and Class A adds Section 36 and high voltage. Pick an answer, then open the explanation. Every question in the bank explains all four options, not just the right one.
Free to read · No account · No email
47 free BC FSR questions in all
-
A journeyperson electrician with a SkilledTradesBC certificate, employed by a licensed contractor, agrees to wire an orchard owner's new irrigation pump house on his days off, billing the orchard himself. He holds no contractor licence, and the orchard holds no permit. Under SSA s.23(1), may he do the job?
- Yes, provided he requests every required inspection himself
- Yes, since his SkilledTradesBC certificate covers that type of work
- No, since he would be working for a client who is not licensed
- No, unless the pump house stays within the Class C limits
Show the answer
C. Correct. SSA s.23(1)(b) bars anyone not licensed by a provincial safety manager, or otherwise authorized under the Act, from doing regulated work for anyone other than a licensed contractor. His certificate lets him do electrical work (ESR s.4(1)(a)); taking a client himself needs a contractor licence, which names an FSR (SSGR s.6).
Source: TSBC FSR exam, Acts, Regulations and Directives (our Unit A: Safety Standards Act and General Regulation); Safety Standards Act s.23; Safety Standards General Regulation s.6; Electrical Safety Regulation s.4
-
A contractor's crew lays only an empty underground raceway from a house to the site of a planned detached workshop; no conductors will be pulled until next spring. Under the ESR s.1 definition of electrical equipment, is laying the raceway regulated electrical work?
- No; a raceway becomes electrical equipment only once conductors are pulled into it
- No; an empty raceway is building material until the circuit it carries is energized
- Yes; conduits intended for carrying electrical energy are electrical equipment
- Yes, but only because the raceway is underground and must later be bonded
Show the answer
C. Correct. ESR s.1 defines electrical equipment for the Act to include apparatus, conduits, pipes, poles and works used, designed or intended for use in generating, transmitting, supplying, distributing or using electrical energy. Work on it is electrical work (ESR s.2).
Source: TSBC FSR exam, Acts, Regulations and Directives (our Unit B: Electrical Safety Regulation, Directives and Bulletins); Electrical Safety Regulation s.1
-
A new house has its service disconnecting means outdoors on a combined meter-main, as Rule 6-206 3) permits, and a feeder runs to a panelboard in the basement. Under D-EL 2016-05, what else does the installation need?
- A directory at the panel locating the outdoor main
- Nothing more; the outdoor main is the service disconnect
- A lockable cover on the outdoor meter-main
- A main disconnecting means inside the house
Show the answer
D. Correct. D-EL 2016-05 reads Rule 6-206 1) b) as requiring that the disconnect can be operated from inside the building, and where the service disconnecting means is outdoors under 6-206 3), a main disconnecting means must also be provided inside the building served. TSBC's bulletin IB-EL 2012-03 repeats that an outdoor disconnect does not remove the need for one.
Source: TSBC FSR exam, Code (our Unit C: BC Electrical Code Rules); CEC Rule 6-206; TSBC D-EL 2016-05, IB-EL 2012-03
-
A new two-storey house has 142 m² of living area and no basement. It has 17 kW of baseboard heaters with room thermostats, a 4.8 kW air conditioner (no interlock), a 12 kW range, a hot tub with a 4 kW water heater, a 5 kW dryer, a 3.8 kW storage-tank water heater and a 24 A EVSE (no EVEMS). What is the calculated load of its 120/240 V service under Rule 8-200 1)?
- 163.4 A
- 170.9 A
- 183.4 A
- 190.7 A
Show the answer
C. Correct. Basic 6000 W (142 m²); heat 10 000 + 0.75 × 7000 = 15 250 W (62-118 3)); air conditioning 4800 W; range 6000 W; hot tub heater 4000 W; 25 % of the 5000 W dryer and 3800 W tank = 2200 W; EVSE 24 × 240 = 5760 W. Method a) 44 010 W exceeds b)'s 24 000 W: 44 010 ÷ 240 V = 183.4 A.
Source: TSBC FSR exam, Code (our Unit D: BC Electrical Code Calculations); CEC Rules 8-200, 62-118, 8-106
-
A strata building is supplied at 120/240 V. Its 182 m² penthouse unit has a 12 kW range, 9 kW of baseboard heat with room thermostats, a deck hot tub with a 5.5 kW water heater and a 5.6 kW dryer; no air conditioning or EVSE. What is the unit's calculated load under Rule 8-202 1)?
- 103.2 A
- 116.3 A
- 120.4 A
- 138.9 A
Show the answer
C. Correct. Basic: 3500 + 1500 + 2 × 1000 = 7000 W (182 m²). Heat 9000 W (under 10 kW). Range 6000 W. Hot tub heater 5500 W at 100 % (item vi)). Dryer 25 % × 5600 = 1400 W. Total 28 900 W ÷ 240 V = 120.4 A, well above the 60 A floor.
Source: TSBC FSR exam, Code (our Unit D: BC Electrical Code Calculations); CEC Rules 8-202, 8-100
Want ten more with every option explained? Free BC FSR practice questions: no account, no email, printable (PDF). With eight more on each unit page below, that makes 47 free BC FSR questions in all.
The BC FSR exam at a glance
How many questions are on the BC FSR exam?
Sixty. Technical Safety BC (TSBC), which sets and delivers the electrical Field Safety Representative exams, gives the same format on its Class A, Class B and Class C pages: 60 multiple-choice questions in 3.5 hours, open book, with a 35% focus on the Act, Regulations and Directives and a 65% focus on the Code, and a minimum grade of 70% to pass. Our timed mock exam is the same length and time. Sources: TSBC's Class B page, with the Class A and Class C pages, and its reference material list (read November 10, 2026).
A Field Safety Representative (FSR) is the person who, on behalf of an employer, declares that regulated electrical work complies with BC's Safety Standards Act and its regulations (Safety Standards General Regulation s. 24). An application for a contractor's licence names one (s. 6), and so does an application for an installation permit (s. 17), and the named FSR is the contractor's representative on code, technical and worker-qualification matters. The class sets what you may declare (Electrical Safety Regulation s. 7): Class A any electrical work; Class B installations up to 1 000 volts, plus underground raceway at any voltage on TSBC's Class B page; Class C single-phase installations of 200 amps or less and 150 volts or less to ground. How to become a Field Safety Representative in BC covers who may write and how a contractor names an FSR.
Open book, with rules. You bring your own current Canadian Electrical Code Part I, the BC Electrical Code since March 4, 2025, when BC adopted the 2024 edition with no deviations. Class A candidates also bring CSA C22.3 No. 1, Overhead Systems. Tabs and highlighting are fine, but pages with written formulas, examples or calculations come out, and the CEC Handbook and Pocket Reference are not allowed. During electrical exams TSBC supplies online links to the Safety Standards Act, the Safety Standards General Regulation, the Electrical Safety Regulation, and its safety orders, directives and information bulletins, so the legislation and the notices are in front of you too.
You write on screen, in person at a TSBC office (Vancouver, Langley, Kelowna, Fort St. John, Prince George, Victoria or Kamloops) or online with remote proctoring, with a non-programmable calculator of your own. On TSBC's electrical fee schedule (updated January 9, 2026), the evaluation of your qualifications is $340 and the exam $193 in person or $183 remote in 2026, plus GST; from January 1, 2027 they are $357, $203 and $192. You get three attempts, each followed by a letter showing the areas that need improvement; after a fail you wait 30 days, and each rewrite is a new exam fee. The BC FSR exam guide has the details.
The full BC FSR practice exam
Find out where you stand on the legislation and the code.
550 original practice questions for the BC FSR exam, 400 Standard and 150 Advanced, across four units on the Acts, Regulations and Directives and the BC Electrical Code, plus a Class A skill set on Section 36 and high voltage, with the reason for every option. Timed mock exams of 60 questions in 3.5 hours, drawn 9, 12, 18 and 21 from units A to D, which is 21 legislation and 39 code questions, TSBC's 35 / 65 split on 60. Each mock is scored against the 70% pass mark with your score on each unit, so a weak one shows up before exam day.
Also writing a Master Electrician or Red Seal exam on TicketPrep? All-Access covers the BC FSR exam for $119, with every other exam on the site included.
What the BC FSR exam covers
TSBC publishes one split: 35% legislation, 65% code.
That split, 35% on the Act, Regulations and Directives and 65% on the Code, is the only weighting TSBC publishes for Classes A, B and C. On a 60-question paper it comes to 21 and 39 questions; that arithmetic is ours. So are the four units below and the way our mock divides each part between them, in proportion to our bank. Treat the unit counts as our study plan, not a TSBC figure.
| Unit | Our unit title | TSBC split | Our mock (of 60) | In our bank |
|---|---|---|---|---|
| A | Safety Standards Act and General Regulation | Act, Regulations and Directives, 35% | 9 | 80 |
| B | Electrical Safety Regulation, Directives and Bulletins | Act, Regulations and Directives, 35% | 12 | 110 |
| C | BC Electrical Code Rules | Code, 65% | 18 | 130 |
| D | BC Electrical Code Calculations | Code, 65% | 21 | 200 |
| E | Class A only: Section 36 and high voltage | Code (Class A) | practice only | 30 |
| Total | 35% + 65% | 60 | 550 |
Split: TSBC's Class A, B and C pages (“35% focus on Act, Regulations, and Directive, and a 65% focus on Code”). The mock follows the Class B and Class C code scope, the whole CEC except Section 36. Class A candidates practise Section 36 and TSBC's high-voltage directive in skill set E; there are no CSA C22.3 No. 1 overhead-systems questions in our bank. Our BC FSR study blueprint (PDF) lists every task we wrote to.
- A
Safety Standards Act and General Regulation · 9 in our mock · 80 in our bank
The scope and definitions of the Act, licensed contractors and certificates of qualification, the FSR's duties under the General Regulation, permissions, permits, inspections and documents, directives, safety orders, variances and incidents, and enforcement: compliance orders, monetary penalties, review and appeal, and offences. Free unit A questions: Safety Standards Act →
- B
Electrical Safety Regulation, Directives and Bulletins · 12 in our mock · 110 in our bank
Who may do regulated electrical work, the FSR classes and certificates, installation, homeowner and operating permits, declarations and inspection requests, the code and approval marks on regulated products, and emergencies, incidents, utilities and recreational vehicles, read with TSBC's active electrical directives and bulletins. Free unit B questions: Electrical Safety Regulation →
- C
BC Electrical Code Rules · 18 in our mock · 130 in our bank
The non-calculation rules of the CEC 2024 as BC's code: Sections 0 and 2, conductors and services (Sections 4 and 6), grounding and bonding, wiring methods, protection and control, Section 26 installations, hazardous locations, motors and the special sections, each read with the BC directives that interpret them. Free unit C questions: code rules →
- D
BC Electrical Code Calculations · 21 in our mock · 200 in our bank
Dwelling, row-housing and apartment loads with EVSE and load management, non-dwelling, add-load and RV park loads, ampacity and correction factors, voltage drop, conduit and box fill, motors, welders and compressors, transformers and taps, and bonding conductors and fault current. Free unit D questions: code calculations →
- E
Class A only: Section 36 and high voltage · not in the B / C mock · 30 in our bank
CEC Section 36 high-voltage installations, read with TSBC's high-voltage directive and bulletin, for Class A candidates to practise as their own skill set. No CSA C22.3 No. 1 questions.
Where our questions come from
Every question original, every one cited.
The units, tasks and sub-tasks in our BC FSR bank are our own grouping, written from public sources: the Safety Standards Act, the Safety Standards General Regulation and the Electrical Safety Regulation on BC Laws, explained in our own words and cited by section; TSBC's active electrical directives and information bulletins, paraphrased and cited by number; and the Canadian Electrical Code, Part I, 2024 edition, the BC Electrical Code since March 4, 2025, cited by rule number and never reproduced. Every question went through a separate, blind verification pass in which every calculation is recomputed. Nothing is copied from courses, workbooks or recalled exam questions. For the exam format, the fees and the rewrite rules, read the BC FSR exam guide; for the classes and who may write, how to become a Field Safety Representative in BC. Read how our questions are made.
Edited by Trevor Mulder · Last checked against Technical Safety BC's Class A, B and C pages, its exam information and reference material pages, its electrical fee schedule (January 9, 2026) and the Electrical Safety Regulation.
Why open book is not easy
The book is there. The time to search it is not.
Sixty questions in 3.5 hours is three and a half minutes each, and a load calculation can take most of that. If you have to hunt for every rule, the clock runs out before the paper does. Many of our questions turn on the BC layer a national code course can skip: a directive that adds an indoor disconnect, a definition in the Electrical Safety Regulation, who may contract for regulated work under the Act. Our explanations give the rule, section or directive behind every option, so you learn where to look as well as what it says, and our mock exams put 60 questions in front of you in 3.5 hours so you find out which units hold up under time.
How TicketPrep prepares you
Built like a study tool, not a quiz app.
Legislation and code
Four units across TSBC's 35 / 65 split, at Standard and Advanced levels, plus a Class A skill set on Section 36 and high voltage.
Every answer explained
Why the right answer is right, and why each of the other three is wrong, with the arithmetic shown on every calculation.
Timed mock exams
60 questions in 3.5 hours, drawn 9, 12, 18 and 21 from units A to D. TSBC publishes only the 35 / 65 split, so the unit counts are ours.
Cited, not copied
Every explanation names the CEC rule, the section of the Act or regulation, or the TSBC directive it rests on, without reproducing their text.
BC FSR exam questions
Before you start.
How many questions are on the BC FSR exam?
What is the pass mark for the FSR exam?
What is on the FSR Class B exam?
Can I bring my code book to the FSR exam?
Does this practice exam cover Class A?
Is the BC FSR practice exam free?
Are these questions from the FSR exam?
What if I fail the FSR exam?
Find out where you actually stand.
Five free questions. No account and no email to start: you see right or wrong as you go and your score at the end. Your email is optional, only to unlock the written explanations. About five minutes.
Then Exam Pass is $69 one-time for 120 days of access, not a subscription, with a 7-day money-back guarantee. Write the FSR exam and don't pass? You get 120 more days free. All-Access covers the BC FSR exam and every other exam on TicketPrep for $119.
Also on TicketPrep